Sugar and organic acid HPLC columns compared

Updated

Ligand exchange vs ion exclusion

Carbohydrate, sugar-alcohol and organic-acid analyses (food, beverage, fermentation, biofuel) usually run on polymer-based ligand-exchange or ion-exclusion columns with water or dilute acid as eluent and RI or UV detection. The counter-ion largely determines selectivity:

  • Ca²⁺ (USP L19) — mono- and disaccharides and sugar alcohols in water.
  • Pb²⁺ — closely related monosaccharides.
  • Na⁺ (USP L58) — oligosaccharides by degree of polymerisation.
  • H⁺ (USP L17) — organic acids, sugars and alcohols together with dilute sulfuric or phosphoric acid; typical for fermentation broths.

Sugar and organic acid columns compared by counter-ion and USP code

Sugar and organic acid columns compared
ColumnPart numberParticle sizeInner diameterLengthpH rangeUSP classificationSeparation modePrice
Shodex SUGAR SC1011 Carbohydrate Column (Ca2+), 8.0 x 300 mm, 6 µmF63781026.0 µm8 mm300 mm3 - 7L19, L22Ligand Exchange (LEX)$1,926.00 USD
Agilent Hi-Plex Ca Carbohydrate Column, 7.7 x 300 mm, 8 µmPL1170-68108.0 µm7.7 mm300 mm7L19Ion Exchange (IEC)$1,764.00 USD
Shodex SUGAR SP0810 Carbohydrate Column (Pb2+), 8.0 x 300 mm, 7 µmF63781057.0 µm8 mm300 mm—L22, L34Ligand Exchange (LEX)$1,926.00 USD
Shodex SUGAR KS-801 Column (Na+), 8.0 x 300 mm, 6 µmF63780106.0 µm8 mm300 mm3 - 7L22, L58Ligand Exchange (LEX)$2,292.00 USD
Shodex SUGAR KS-802 Column (Na+), 8.0 x 300 mm, 6 µmF63780206.0 µm8 mm300 mm3 - 7L22, L58Ligand Exchange (LEX)$2,292.00 USD
Shodex SUGAR SH1011 Organic Acid & Sugar Column (H+), 8.0 x 300 mm, 6 µmF63781006.0 µm8 mm300 mm—L17, L22Ion Exchange (IEC)$1,926.00 USD
Agilent Hi-Plex H Column for Sugars & Organic Acids, 7.7 x 300 mm, 8 µmPL1170-68308.0 µm7.7 mm300 mm0 - 7L17, L22Ion Exchange (IEC)$1,764.00 USD
Shodex RSpak KC-811 Organic Acid Column, 8.0 x 300 mm, 6 µmF63780306 µm—————Quote

Do not forget the guard

Polymer columns are expensive and sensitive to particulates and proteins. Pair them with the matching guard: Shodex SUGAR SC-G 6B Guard Column (Ca2+), 6.0 x 50 mm, 10 µm (F6700090), Shodex SUGAR KS-G 6B Guard Column (Na+), 6.0 x 50 mm, 10 µm (F6700020) or Shodex SUGAR SH-G Guard Column (H+), 6.0 x 50 mm, 10 µm (F6700080). A refractive index detector such as the Shodex RI-201H Refractive Index Detector (F4010106) is the usual detector for sugars.

Browse all Shodex columns.

Frequently asked questions

Which HPLC column is best for sugar analysis?

Ligand-exchange columns in the calcium form (for example Shodex SUGAR SC1011 or Agilent Hi-Plex Ca, USP L19) are the usual choice for mono- and disaccharides and sugar alcohols with water as eluent and RI detection.

Can I analyse organic acids and sugars in one run?

Yes. Hydrogen-form ion-exclusion columns such as Shodex SUGAR SH1011 or Agilent Hi-Plex H (USP L17) separate organic acids, sugars and alcohols together using a dilute acid eluent, which is typical for fermentation samples.