Shimadzu LC systems are among the most widely installed in QC labs. Keeping the right consumables on the shelf prevents most unplanned downtime. This guide lists the items to stock, with Shimadzu part numbers where they are published, and clearly separates genuine Shimadzu items from compatible parts made by other manufacturers.
Shim-pack columns
- General purpose HPLC: Shimadzu Shim-pack GIST C18 HPLC Column, 4.6 x 150 mm, 5 µm (
227-30017-07), Shimadzu Shim-pack GIST C18 HPLC Column, 4.6 x 250 mm, 5 µm (227-30017-08), aqueous-stable Shimadzu Shim-pack GIST C18-AQ HPLC Column, 4.6 x 250 mm, 5 µm (227-30742-08). - UHPLC / LC-MS: Shimadzu Shim-pack GIST C18 UHPLC Column, 2.1 x 100 mm, 2 µm (
227-30001-04), Shimadzu Shim-pack Velox C18 Core-Shell Column, 2.1 x 100 mm, 2.7 µm (227-32009-03), Shimadzu Shim-pack Scepter C18 UHPLC Column, 2.1 x 100 mm, 1.9 µm (227-31012-05). - Alternative selectivity: Shimadzu Shim-pack Velox Biphenyl Core-Shell Column, 2.1 x 100 mm, 2.7 µm (
227-32015-03), Shimadzu Shim-pack Scepter PFPP Column, 2.1 x 100 mm, 3 µm (227-31055-05).
Vials and closures
Shimadzu autosamplers use 1.5 mL vials in standard racks. Genuine kits: Shimadzu Certified Vial Kit for LC/LC-MS, 1.5 mL (100/pk) (227-34001-01), low-adsorption Shimadzu Shim-vial H Low-Adsorption Certified Vial Kit, 1.5 mL (100/pk) (227-34500-01), Shimadzu Micro Insert, Clear Glass, 0.1 mL for 1.5 mL Vials (100/pk) (961-10020-27) and the polypropylene Shimadzu Vial Kit for PFAS Analysis, Clear Plastic, 1.5 mL (100/pk) (961-10010-34). A priced compatible alternative is Altmann Analytik 1.5 mL Short-Thread Certified Vial Kit with UltraClean Seal, 100/kit (AAV22513667).
Fittings and mobile-phase accessories
Shimadzu EXP Hand-Tight Fitting with Ferrule (1 pc) (980-20506), Shimadzu EXP-2 TI-LOK Hand-Tight Fitting (2/pk) (980-33018) and the Shimadzu Ghost Trap DS-HP Mobile-Phase Cleaner, 30 x 2.1 mm (228-59931-91) for removing ghost peaks in gradient methods.
Pump wear parts (LC-10AD / LC-20AD / LC-30AD)
Plunger seals and check valves are the most frequently replaced pump parts. Compatible (Altmann Analytik) parts cross-referenced to Shimadzu part numbers:
- Altmann Analytik Plunger Seal for Shimadzu LC-10AD/LC-20AD/LC-2010 (equiv. 228-35146) (
228-35146ASP) and Altmann Analytik Gold Plunger Seal for Shimadzu LC-10ADvp / LC-20AD/AB (equiv. 228-32628-00) (228-32628-00ASP) - Altmann Analytik Outlet Check Valve for Shimadzu LC-20AD XR / LC-30AD / i-Series (equiv. 228-45705-91) (
228-45705-91ASP) and Altmann Analytik Inlet Check Valve for Shimadzu LC-20AD XR / LC-30ADSF / i-Series (equiv. 228-48249-96) (228-48249-96ASP) - Altmann Analytik Stainless Steel Suction Filter for Shimadzu LC-10/LC-20 Pumps (equiv. 228-45707-91) (
228-45707-91ASP), Altmann Analytik Line Filter Assembly for Shimadzu LC Systems (equiv. 228-35871-96) (228-35871-96ASP), Altmann Analytik PTFE Diaphragm for Shimadzu LC-20AD/LC-30AD Pumps, 2/pk (equiv. 228-32784-91) (228-32784-91ASP)
Autosampler parts (SIL-10A / SIL-20A)
Altmann Analytik PEEK Needle Seal for Shimadzu SIL-20A/AC Autosampler (equiv. 228-42325-01) (228-42325-01ASP), Altmann Analytik Platinum-Coated Needle for Shimadzu SIL-20A/AC (equiv. 228-41024-93) (228-41024-93ASP), Altmann Analytik Rotor Seal for Shimadzu SIL-10A / SIL-10AXL Autosampler (equiv. 228-21217-91) (228-21217-91ASP).
Detector lamps
Deuterium lamps for SPD-10A/SPD-20A detectors are offered by several manufacturers: Restek Long-Life D2 Lamp for Shimadzu SPD-10A/20A Detectors, 2000 h (25284), Agilent Deuterium Lamp for Shimadzu SPD-20A/AV Detectors, 2000 h (8001-0702), Altmann Analytik Deuterium Lamp for Shimadzu SPD-10A / SPD-20A, 2000 h (equiv. 228-34016-02) (228-34016-02ASP), Thomson Long-Life Deuterium Lamp for Shimadzu SPD-10A/10AV/M10Avp (004-0075). i-Series users: Altmann Analytik Deuterium Lamp Assembly for Shimadzu i-Series LC-2030/2040/2050/2060 (equiv. 228-55626-00) (228-55626-00ASP).
Suggested preventive-maintenance kit
- Two plunger seals per pump head, plus a set of check valves.
- Suction (inlet) filters for every solvent line.
- Needle seal and rotor seal for the autosampler.
- One spare D2 lamp per UV/PDA detector.
- Certified vials and a spare guard cartridge for each critical method.
For seals, check valves, needles and lamps listed by instrument model, see Shimadzu LC maintenance parts by instrument. See all Shimadzu columns, parts & consumables or Shimadzu instruments. Need a genuine Shimadzu part not listed? Request a quote with the 228-/227-/980- part number.
Frequently asked questions
How do I find the right Shimadzu part number?
Use the part number from your instrument manual, parts list or a previous order (for example 228-35146 for an LC-20AD plunger seal) and search it here. Compatible parts list the Shimadzu number they replace.
When should Shimadzu pump plunger seals be replaced?
Replace them as part of preventive maintenance at the interval Shimadzu recommends for your model, or sooner if you see leaks at the pump head, pressure ripple or flow problems.
Are compatible parts as good as genuine Shimadzu parts?
Compatible parts are made by independent manufacturers to replace the Shimadzu part number shown. They are clearly labelled here; if your method or service contract requires genuine parts, choose the Shimadzu-branded item.