HPLC vials, caps and septa: how to choose

Updated

Vials and closures are the consumable a chromatography lab reorders most often, and the wrong combination causes some of the most annoying problems: needle damage, cored septa, evaporation and ghost peaks. This guide walks through the choices in the order that matters, with example part numbers from the vials, caps & inserts category.

1. Match the vial format to your autosampler

The 2 mL screw-top vial (12 x 32 mm, 9 mm thread) is the default for most HPLC and LC-MS autosamplers, for example Agilent 2 mL Clear Screw-Top Vials, Certified, 100/pk (5182-0714). Some Shimadzu autosamplers use 1.5 mL vials, such as the Shimadzu Certified Vial Kit for LC/LC-MS, 1.5 mL (100/pk) (227-34001-01) or the compatible Altmann Analytik 1.5 mL Short-Thread Certified Vial Kit with UltraClean Seal, 100/kit (AAV22513667), and some use 8-425 caps (Thermo Scientific White Screw Caps with Septa for Shimadzu Autosamplers, 8-425, 100/pk (C4013-63W)). Check the rack and needle settings in your instrument manual before switching formats.

2. Clear or amber glass

Amber glass protects light-sensitive samples and standards (Agilent 2 mL Amber Screw-Top Vials with Write-On Spot, Certified, 100/pk (5182-0716)). A write-on spot makes manual labelling easier (Agilent 2 mL Clear Screw-Top Vials with Write-On Spot, Certified, 100/pk (5182-0715)).

3. Choose the cap and septum

4. Small sample volumes: inserts and total-recovery vials

When you only have a few hundred microlitres, a glass insert lets the needle draw from a small volume: Agilent 250 µL Pulled-Point Glass Vial Inserts, 100/pk (5183-2085), Agilent 250 µL Glass Inserts with Polymer Feet, 100/pk (5181-1270) or Macherey-Nagel 0.2 mL Conical Glass Insert for Wide-Opening Vials, 100/pk (702813). Total-recovery vials such as Waters LCGC Certified Total Recovery Vials, 12 x 32 mm, 100/pk (186000384C) are shaped to minimise the volume left behind.

5. LC-MS and low-adsorption vials

For LC-MS, choose vials certified for low background, such as Waters TruView Amber LCMS Certified Vials with PTFE/Silicone Septa Caps, 100/pk (186005667CV). Low-adsorption vials (Shimadzu Shim-vial H Low-Adsorption Certified Vial Kit, 1.5 mL (100/pk) (227-34500-01)) help with analytes that stick to glass, and polypropylene vials (Shimadzu Vial Kit for PFAS Analysis, Clear Plastic, 1.5 mL (100/pk) (961-10010-34)) are used for PFAS work. Pair them with LC-MS grade solvents and filtered samples (syringe filter selection guide). Check thread and septum sizes in autosampler vial sizes & compatibility.

Frequently asked questions

What is the standard HPLC vial size?

The 2 mL screw-top vial, 12 x 32 mm with a 9 mm thread, fits most HPLC and LC-MS autosamplers. Some Shimadzu racks use 1.5 mL vials; check your autosampler manual.

What septa are best for HPLC vials?

PTFE/silicone septa are the general-purpose choice for HPLC and LC-MS. Pre-slit septa help with repeated injections from the same vial and with viscous samples, and bonded cap/septa reduce the risk of the septum falling into the vial.

Should I use clear or amber vials?

Use amber glass for light-sensitive samples and standards; clear glass makes it easier to see the sample level and any particles. Both are available in the same 2 mL format.

Can I reuse HPLC vials?

Most labs use autosampler vials once, because cleaning can leave residues that show up as ghost peaks. Certified vials are tested for cleanliness and dimensional tolerances, which is why they are preferred for regulated and LC-MS work.